C-2R REPORT: COMPUTER PERFORMANCE SUMMARY
The C-2R Report shows if the proposed building design complies with the Computer
Performance Method of compliance. This MICROPAS report also provides a detailed list
of the energy related building data used for the analysis. This building data is verified by the building department
during plan check. |
back
next report
|
COMPUTER METHOD SUMMARY Page 1 C-2R
===============================================================================
Project Title.......... Example Run Date..07/01/99 07:48:20
Project Address........ 2300 Mace Ave ******* ---------------------
Modesto CA *v5.00* | _________________ |
Documentation Author... Samuel T. Smith ******* | Building Permit # |
Enercomp, Inc. | _________________ |
1721 Arroyo Drive | Plan Check / Date |
Auburn, CA 95603 | _________________ |
888-888-8888 | Field Check/ Date |
Climate Zone........... 12 ---------------------
Compliance Method...... MICROPAS5 v5.00 for 1999 Standards by Enercomp, Inc.
===============================================================================
| MICROPAS5 v5.00 File-MP5BASE Wth-CTZ12S92 Program-FORM C-2R |
| User#-MP0101 User-Enercomp, Inc. Run-Base Case |
-------------------------------------------------------------------------------
=================================================================
= MICROPAS5 ENERGY USE SUMMARY =
= ---------------------------- =
= Energy Use Standard Proposed Compliance =
= (kBtu/sf-yr) Design Design Margin =
= ----------------------- ---------- ---------- ---------- =
= Space Heating.......... 18.06 18.80 -0.74 =
= Space Cooling.......... 7.17 6.21 0.96 =
= Water Heating.......... 15.08 13.56 1.52 =
= -------- -------- -------- =
= Total 40.31 38.57 1.74 =
= =
= *** Building complies with Computer Performance *** =
=================================================================
GENERAL INFORMATION
-------------------
Conditioned Floor Area..... 1600 sf
Building Type.............. Single Family Detached
Construction Type ......... New
Building Front Orientation. Front Facing 0 deg (N)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type.... Slab On Grade
Number of Building Zones... 1
Conditioned Volume......... 12800 cf
Slab-On-Grade Area......... 1600 sf
Glazing Percentage......... 16.5 % of floor area
Average Glazing U-value.... 0.84 Btu/hr-sf-F
Average Glazing SHGC....... 0.71
Average Ceiling Height..... 8 ft
COMPUTER METHOD SUMMARY Page 2 C-2R
===============================================================================
Project Title.......... Example Run Date..07/01/99 07:48:20
===============================================================================
| MICROPAS5 v5.00 File-MP5BASE Wth-CTZ12S92 Program-FORM C-2R |
| User#-MP0101 User-Enercomp, Inc. Run-Base Case |
-------------------------------------------------------------------------------
BUILDING ZONE INFORMATION
-------------------------
Floor # of Vent Vent Air
Area Volume Dwell Cond- Thermostat Height Area Leakage
Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit
-------------- ----- ------- ----- ------- ----------- ----- -------- ---------
HOUSE
Residence 1600 12800 1.00 Yes Setback 2.0 Standard No
OPAQUE SURFACES
---------------
Area U- Insul Act Solar Form 3 Location/
Surface (sf) value R-val Azm Tilt Gains Reference Comments
-------------- ------ ----- ----- --- ---- ----- ------------ ----------------
HOUSE
1 Wall 204 0.059 21 0 90 Yes W.21.2X6.16
2 Wall 264 0.059 21 90 90 Yes W.21.2X6.16
3 Wall 192 0.059 21 180 90 Yes W.21.2X6.16
4 Wall 288 0.059 21 270 90 Yes W.21.2X6.16
5 Wall 37 0.059 21 45 90 Yes W.21.2X6.16 Corner Wall
6 Roof 1592 0.029 38 n/a 0 Yes R.38.2X12.16 Attic
7 Door 20 0.330 0 0 90 Yes None Solid Wood
PERIMETER LOSSES
----------------
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ ------ -------- ------- ----- ----------------------
HOUSE
8 SlabEdge 160 0.760 R-0 No To Outside
FENESTRATION SURFACES
---------------------
Area U- Act Exterior Shade Interior Shade
Orientation (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC
---------------------- ----- ----- ----- --- ---- -------------- --------------
HOUSE
1 Window Front (N) 24.0 0.870 0.700 0 90 Standard/0.76 Standard/0.68
2 Window Front (N) 40.0 0.720 0.730 0 90 Standard/0.76 Standard/0.68
3 Window Left (E) 24.0 0.870 0.700 90 90 Standard/0.76 Blind/0.47
4 Window Back (S) 48.0 0.870 0.700 180 90 Standard/0.76 Blind/0.47
5 Door Back (S) 80.0 0.850 0.700 180 90 Standard/0.76 Standard/0.68
6 Window Right (W) 32.0 0.870 0.700 270 90 Woven/0.3 Standard/0.68
7 Window Front (NE) 8.0 0.720 0.730 45 90 Standard/0.76 Standard/0.68
8 Skylight Front (N) 8.0 0.940 0.730 0 23 None/1 None/1
COMPUTER METHOD SUMMARY Page 3 C-2R
===============================================================================
Project Title.......... Example Run Date..07/01/99 07:48:20
===============================================================================
| MICROPAS5 v5.00 File-MP5BASE Wth-CTZ12S92 Program-FORM C-2R |
| User#-MP0101 User-Enercomp, Inc. Run-Base Case |
-------------------------------------------------------------------------------
OVERHANGS AND SIDE FINS
-----------------------
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin--
Area Left Rght
Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
HOUSE
1 Window 24.0 n/a 4.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a
2 Window 40.0 n/a 5.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a
3 Window 24.0 n/a 5.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
4 Window 48.0 n/a 4.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
5 Door 80.0 n/a 6.7 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
6 Window 32.0 n/a 4.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
SLAB SURFACES
-------------
Area
Slab Type (sf)
---------------- ------
HOUSE
Standard Slab 1600
HVAC SYSTEMS
------------
Minimum Duct Duct Tested Duct ACCA Duct
System Type Efficiency Location R-value Leakage Manual D Eff
---------------- ------------ ------------- ------- --------- --------- -------
HOUSE
Furnace 0.780 AFUE Attic R-4.2 No No 0.743
ACSplit 10.00 SEER Attic R-4.2 No No 0.674
WATER HEATING SYSTEMS
---------------------
Number Tank External
in Energy Size Insulation
Tank Type Heater Type Distribution Type System Factor (gal) R-value
------------ ----------- ------------------- ------ -------- ------ ----------
1 Storage Gas Standard 1 0.58 50 R- n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates non-standard Fenestration Shading.
REMARKS
-------
_______________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________
|